Gas and Gadgets
 
0
Safety Tips
Important Links
Safety Tips
You are here : Safety Tips >   Safety Tips for Non Domestic Customers
Safety Tips
For LPG installation and appliances
    Always use BIS/ Industry approved appliances
    Obtain BIS/ Industry approved pig-tails and regulators / adaptors from Authorised Indane Distributors/ suppliers or Indane service providers
    Never use screw-type adaptors
Safe Operation of LPG Installation
    There should be NO SMOKING and NO Ignition Sources near the LPG Cylinder Bank Storage
    Do Not Allow rubbish or flammable materials to accumulate around the LPG Cylinder Bank Storage
    Keep foliage from growing around or over the LPG Cylinder Bank Storage
    Do not paint the LPG cyliders or obscure any signs or labels attached to it.
    Keep access to the LPG Cylinder Bank Storage free at all times
    Arrange for regular servicing of all your LPG appliances including pipelines
    Any Faults or Damage to the LPG Cylinders should be reported to IOCL Instantly
    If the premises of LPG Cylinder Bank Storage are to be Left Unattended for a long period, Turn off the gas supply at the Emergency Stop Valve
While receiving cylinders
    Only authorised personnel should enter into the Indane LPG installation
    Check for the cylinder has been delivered with the appropriate company safety cap and seal intact
    Check for any visible signs of leakage - through Visual Inspection, Water, Soap Solution or Smell
    Do Not Put Soap solution In the Valve. Put Some water instead
    Check to see that rubber ‘O’ ring inside the cylinder valve is present
    If you are not sure about usage, please ask the delivery person for a demonstration
    Don’t move or shift the cylinders by dragging, rolling on body or dropping from height. Always try using ramp installed in truck for cylinder loading and unloading
Before Usage
    Check to see that rubber ‘O’ ring inside the cylinder valve is present
    Check for any visible signs of leakage - through Visual Inspection, Water, Soap Solution or Smell
    Do Not Put Soap solution In the Valve. Put Some water instead
    Always keep the cylinder in upright position at ground level at a well ventilated place
    The cylinder must be kept away from other any sources of heat
During Usage
    Never heat the cylinders to get more flow of gas
    Never use the cylinders in horizontal position
    Use all cylinders in LPG Cylinder banks at the time of use
    Loose isolated Cylinders should not be used for Industrial Usage
    Proper approved Hose should be used
After Usage
    Close all regulators knobs or the mains valve to ‘OFF’ position when LPG is not in use
    The empty cylinders must remain in the designated Cylinder Bank or be stored in well ventilated place with safety cap put ON
Maintenance
    Get your gas appliances periodically serviced from Authorised Indane Distributors only
    Get your LPG manifold periodically serviced from Authorised Indane Distributors only
    Before carrying out any maintenance work, a work permit shall be obtained from Authorised Indane Distributors
    All maintenance operations inside the LPG yard must be carried out by authorised Trained service personnel only
    No hot work like welding, cutting, heating should be carried out inside the LPG installation (Safety Zone/ fenced area)
    All maintenance work for burners or combustion system should be carried out through authorised service personnel of your Indane Distributor
In case of Leakage
    Do not Panic
    Do not Switch On or Switch Off any electrical appliances in the room
    Isolate main electrical supply from the outside only
    Extinguish all flames, open lamps etc
    Close all the appliances and LPG regulator
    Put On the Safety Cap on the cylinder
    Open all Doors & Windows for ventilation
    Never use fan for ventilation
    Call your Indane Gas Distributor / Emergency Service Cell during their Working hours or IOCL Officials in case first Two options Fail for Help
In case of Fire
    Evacuate the building
    Call the fire brigade
    Turn off the gas supply at the emergency stop valve if it is safe to do so
    Advise the Fire Officer of the existence of an LPG Cylinder Bank
    Contact IOCL
To refill your cylinder fill the form and get your booking No.
To refill your cylinder fill the form and get your booking No.
To refill your cylinder fill the form and get your booking No.
Book your cylinder by SMS
Book your cylinder Online
view our ISO Certification ...
Home  |   Management Structure  |    CSR  |    Production Figure  |    Sitemap  |    Feedback  |   Contact Us
Site best viewed by 1024 x 768 resolution and above, Site designed and developed by Micro Research Associates

Contact: Mr. Bijan Behari Biswas, Ph. 9830064144
E-mail : bijanbb@yahoo.com, bijanbb@gasandgadgets.com